Resource ID Access Type Multiple Instances Mandatory Type Description
Device 20170 R Single Mandatory Objlink The device description of the EMM.
LogControl 20171 / Multiple Mandatory Objlink Sensor log control link.
DeviceBind 20172 / Multiple Mandatory Objlink Binding the EMM to a physical device it measures.
VoltageSensor 20173 / Multiple mandatory Objlink The integrated voltage sensor.
CurrentSensor 20174 / Multiple Mandatory Objlink The integrated current sensor.
PowerSensor 20175 / Multiple Mandatory Objlink The integrated power sensor.
The EMM Integrator Object creates a logical representation of the EMM using object links. The objects being linked are the Device Binding Object, Log Control and the IPSO Sensors.